| HIDROGEN GENERATORS ALL MODELS |
|
MODEL 0,6 GENERATOR |
Technical features |
Unit |
Max hydrogen production |
0,400 |
m3/h |
Max oxygen production |
0,200 |
m3/h |
Max Pressure |
1,8 |
bar (g) |
Control System |
standard |
|
Gas purity |
≥ 99,5 |
% |
Dew Point - outlet |
Environmental temperature |
° C |
Supply Voltage |
Single phase 230 - 50 |
V - Hz |
Max electrical consumption |
3 |
Kwh |
Max electrical Current |
|
A |
Switch breaker |
|
A |
Protecion grade against moisture |
2.0 IP |
|
Max water consumption
(< 5 μS/cm) |
0,38 |
l/h |
Cooling system |
Air |
|
Noise level |
|
dBA |
Dimensions
(l x w x h) |
85 x 75 x 75 |
cm |
Weight |
85 |
Kg |
MODEL 1,6 GENERATOR |
Technical features |
Unit |
Max hydrogen production |
1,060 |
m3/h |
Max oxygen production |
0,540 |
m3/h |
Max Pressure |
1,8 |
bar (g) |
Control System |
standard |
|
Gas purity |
≥ 99,5 |
% |
Dew Point - outlet |
Environmental temperature |
° C |
Supply Voltage |
Trhee phase 400 - 50 |
V - Hz |
Max electrical consumption |
6 |
Kwh |
Max electrical Current |
|
A |
Switch breaker |
|
A |
Protecion grade against moisture |
2.0 IP |
|
Max water consumption
(< 5 μS/cm) |
1 |
l/h |
Cooling system |
Air |
|
Noise level |
|
dBA |
Dimensions
(l x w x h) |
110 x 90 x 110 |
cm |
Weight |
290 |
Kg |
MODEL 3,7 GENERATOR |
Technical features |
Unit |
Max hydrogen production |
2,460 |
m3/h |
Max oxygen production |
1,230 |
m3/h |
Max Pressure |
1,8 |
bar (g) |
Control System |
standard |
|
Gas purity |
≥ 99,5 |
% |
Dew Point - outlet |
Environmental temperature |
° C |
Supply Voltage |
Trhee phase 400 - 50 |
V - Hz |
Max electrical consumption |
14 |
Kwh |
Max electrical Current |
|
A |
Switch breaker |
|
A |
Protecion grade against moisture |
2.0 IP |
|
Max water consumption
(< 5 μS/cm) |
2,2 |
l/h |
Cooling system |
Air |
|
Noise level |
|
dBA |
Dimensions
(l x w x h) |
115 x 95 x 140 |
cm |
Weight |
420 |
Kg |
MODEL 4,2 GENERATOR |
Technical features |
Unit |
Max hydrogen production |
2,800 |
m3/h |
Max oxygen production |
1,400 |
m3/h |
Max Pressure |
1,8 or 4,0 |
bar (g) |
Control System |
standard |
|
Gas purity |
≥ 99,5 |
% |
Dew Point - outlet |
Environmental temperature |
° C |
Supply Voltage |
Trhee phase 400 - 50 |
V - Hz |
Max electrical consumption |
16 |
Kwh |
Max electrical Current |
|
A |
Switch breaker |
|
A |
Protecion grade against moisture |
2.0 IP |
|
Max water consumption
(< 5 μS/cm) |
2,5 |
l/h |
Cooling system |
Air |
|
Noise level |
|
dBA |
Dimensions
(l x w x h) |
115 x 95 x 140 |
cm |
Weight |
460 |
Kg |
MODEL 5,5 GENERATOR |
Technical features |
Unit |
Max hydrogen production |
3,670 |
m3/h |
Max oxygen production |
1,830 |
m3/h |
Max Pressure |
1,8 or 4,0 |
bar (g) |
Control System |
standard |
|
Gas purity |
≥ 99,5 |
% |
Dew Point - outlet |
Environmental temperature |
° C |
Supply Voltage |
Trhee phase 400 - 50 |
V - Hz |
Max electrical consumption |
22 |
Kwh |
Max electrical Current |
|
A |
Switch breaker |
|
A |
Protecion grade against moisture |
2.0 IP |
|
Max water consumption
(< 5 μS/cm) |
3,3 |
l/h |
Cooling system |
Air |
|
Noise level |
|
dBA |
Dimensions
(l x w x h) |
115 x 95 x 140 |
cm |
Weight |
500 |
Kg |
MODEL 8.0 GENERATOR |
Technical features |
Unit |
Max hydrogen production |
5,300 |
m3/h |
Max oxygen production |
2,700 |
m3/h |
Max Pressure |
4,0 |
bar (g) |
Control System |
PLC with ICS - Idroenergy communication System |
|
Gas purity |
≥ 99,5 |
% |
Dew Point - outlet |
Environmental temperature |
° C |
Supply Voltage |
Trhee phase 400 - 50 |
V - Hz |
Max electrical consumption |
28 |
Kwh |
Max electrical Current |
46 |
A |
Switch breaker |
Type “D” - 100 |
A |
Protecion grade against moisture |
2.0 IP |
|
Max water consumption
(< 5 μS/cm) |
4,5 |
l/h |
Cooling system |
Water or Air |
|
Noise level |
< 70 |
dBA |
Dimensions
(l x w x h) |
125 x 95 x 130 |
cm |
Weight |
620 |
Kg |
MODEL 11.0 GENERATOR |
Technical features |
Unit |
Max hydrogen production |
7,400 |
m3/h |
Max oxygen production |
3,600 |
m3/h |
Max Pressure |
4, or 6 |
bar (g) |
Control System |
PLC with ICS - Idroenergy communication System |
|
Gas purity |
≥ 99,5 |
% |
Dew Point - outlet |
Environmental temperature |
° C |
Supply Voltage |
Trhee phase 400 - 50 |
V - Hz |
Max electrical consumption |
40 |
Kwh |
Max electrical Current |
70 |
A |
Switch breaker |
Type “D” - 160 |
A |
Protecion grade against moisture |
2.0 IP |
|
Max water consumption
(< 5 μS/cm) |
6,1 |
l/h |
Cooling system |
Water or Air |
|
Noise level |
< 70 |
dBA |
Dimensions
(l x w x h) |
220 x 100 x 150 |
cm |
Weight |
1180 |
Kg |
MODEL 15.0 GENERATOR |
Technical features |
Unit |
Max hydrogen production |
10,00 |
m3/h |
Max oxygen production |
5,000 |
m3/h |
Max Pressure |
4, or 6 |
bar (g) |
Control System |
PLC with ICS - Idroenergy communication System |
|
Gas purity |
≥ 99,5 |
% |
Dew Point - outlet |
Environmental temperature |
° C |
Supply Voltage |
Trhee phase 400 - 50 |
V - Hz |
Max electrical consumption |
55 |
Kwh |
Max electrical Current |
90 |
A |
Switch breaker |
Type “D” - 160 |
A |
Protecion grade against moisture |
2.0 IP |
|
Max water consumption
(< 5 μS/cm) |
8,5 |
l/h |
Cooling system |
Water or Air |
|
Noise level |
< 70 |
dBA |
Dimensions
(l x w x h) |
220 x 100 x 150 |
cm |
Weight |
1250 |
Kg |
MODEL 19.0 GENERATOR |
Technical features |
Unit |
Max hydrogen production |
12,670 |
m3/h |
Max oxygen production |
6,330 |
m3/h |
Max Pressure |
4, or 8 |
bar (g) |
Control System |
PLC with ICS - Idroenergy communication System |
|
Gas purity |
≥ 99,5 |
% |
Dew Point - outlet |
Environmental temperature |
° C |
Supply Voltage |
Trhee phase 400 - 50 |
V - Hz |
Max electrical consumption |
67 |
Kwh |
Max electrical Current |
95 |
A |
Switch breaker |
Type “D” - 160 |
A |
Protecion grade against moisture |
2.0 IP |
|
Max water consumption
(< 5 μS/cm) |
10 |
l/h |
Cooling system |
Water |
|
Noise level |
< 70 |
dBA |
Dimensions (l x w x h) |
220 x 120 x 210 |
cm |
Weight (Production unit – Control Unit - Transformer) |
1450 |
Kg |
MODEL 33.0 GENERATOR |
Technical features |
Unit |
Max hydrogen production |
22,000 |
m3/h |
Max oxygen production |
11,000 |
m3/h |
Max Pressure |
4, or 6 |
bar (g) |
Control System |
PLC with ICS - Idroenergy communication System |
|
Gas purity |
≥ 99,5 |
% |
Dew Point - outlet |
Environmental temperature |
° C |
Supply Voltage |
Trhee phase 400 - 50 |
V - Hz |
Max electrical consumption |
125 |
Kwh |
Max electrical Current |
190 |
A |
Switch breaker |
Type “D” - 250 |
A |
Protecion grade against moisture |
2.0 IP |
|
Max water consumption
(< 5 μS/cm) |
20 |
l/h |
Cooling system |
Water |
|
Noise level |
< 70 |
dBA |
Dimensions (l x w x h)
Production Unit
Drive & Control Unit
Transformer |
245 x 150 x 215
90 x 60 x 210
95 x 85 x 115 |
cm |
Weight (Production unit – Control Unit - Transformer) |
2000 – 200 – 900 |
Kg |
MODEL 66.0 GENERATOR |
Technical features |
Unit |
Max hydrogen production |
44,000 |
m3/h |
Max oxygen production |
22,000 |
m3/h |
Max Pressure |
4, or 6 |
bar (g) |
Control System |
PLC with ICS - Idroenergy communication System |
|
Gas purity |
≥ 99,5 |
% |
Dew Point - outlet |
Environmental temperature |
° C |
Supply Voltage |
Trhee phase 380-400/ 50 |
V - Hz |
Max electrical consumption |
250 |
Kwh |
Max electrical Current |
420 |
A |
Switch breaker |
Type “D” - 500 |
A |
Protecion grade against moisture |
2.0 IP |
|
Max water consumption
(< 5 μS/cm) |
42 |
l/h |
Cooling system |
Water |
|
Noise level |
< 70 |
dBA |
Dimensions (l x w x h)
Production Unit
Drive & Control Unit
Transformer |
320 x 180 x 270
85 x 110 x 230
130 x 110 x 140 |
cm |
Weight (Production unit – Control Unit - Transformer) |
3200 – 200 – 1400 |
Kg |
MODEL 120.0 GENERATOR |
Technical features |
Unit |
Max hydrogen production |
80,000 |
m3/h |
Max oxygen production |
40,000 |
m3/h |
Max Pressure |
4, or 6 |
bar (g) |
Control System |
PLC with ICS - Idroenergy communication System |
|
Gas purity |
≥ 99,5 |
% |
Dew Point - outlet |
Environmental temperature |
° C |
Supply Voltage |
Trhee phase 380-400/ 50 |
V - Hz |
Max electrical consumption |
45 |
Kwh |
Max electrical Current |
768 |
A |
Switch breaker |
Type “D” - 500 |
A |
Protecion grade against moisture |
2.0 IP |
|
Max water consumption
(< 5 μS/cm) |
76 |
l/h |
Cooling system |
Water |
|
Noise level |
< 70 |
dBA |
Dimensions (l x w x h)
Production Unit
Drive & Control Unit
Transformer |
550 x 170 x 300
100 x 80 x 230
130 x 140 x 170 |
cm |
Weight (Production unit – Control Unit - Transformer) |
6000 – 500 – 1800 |
Kg |
|
| |
|
|
|
|